Hot water · WNS series
WNS Pressurized Oil/Gas Fired Hot Water Boiler
Horizontal pressurised fire tube gas hot water boiler, also for diesel — 13 standard sizes.

- Output
- 0.35–14 MW
- Working pressure
- 0.7–1 MPa
- Standard sizes
- 13
- Fuel
- Natural gas · Diesel
Design
CWNS series hot water boiler is three-pass all wet back shell type structure.
- Medium
- Hot water
- Fuel
- Natural gas / LPG, Diesel / heavy oil
- Output
- 0.35–14 MW
- Working pressure
- 0.7–1 MPa
- Standard sizes
- 13 · WNS0.35 – WNS14
Main body includs boiler shell, furnace, boiler smoke chamber and convection bank. convection smoke tube is made by threaded pipes, enhance heat transfer. More than 90% thermal efficiency. Intelligent, fully automatic control, over-temperature stand by.
Address:9na Calle Poniente y 4ta Ave. Norte # 2-14C, Santa Tecla, La Libertad EI Salvador
Features
Swipe →Gallery
WNS Pressurized Oil/Gas Fired Hot Water Boiler
6 images
Technical parameters
WNS series
Every standard size with output, pressure, fuel consumption, connections, dimensions and weight. Boilers are built to order — the quotation confirms the final figures.
Ask for drawings →Swipe the table for all sizes
| Model | WNS0.35-0.7-95/70-Y(Q) | WNS0.48-0.7-95/70-Y(Q) | WNS0.7-0.7-95/70-Y(Q) | WNS1.05-1.0-95/70-Y(Q) | WNS1.4-1.0-95/70-Y(Q) | WNS2.1-1.0-115/70-Y(Q) | WNS2.8-1.0-115/70-Y(Q) | WNS3.5-1.0-115/70-Y(Q) | WNS4.2-1.0-115/70-Y(Q) | WNS5.6-1.0-115/70-Y(Q) | WNS7-1.0-115/70-Y(Q) | WNS10.5-1.0-115/70-Y(Q) | WNS14-1.0-115/70-Y(Q) | ||
| Item | Unit | ||||||||||||||
| Rated thermal power | MW | 0.35 | 0.48 | 0.7 | 1.05 | 1.4 | 2.1 | 2.8 | 3.5 | 4.2 | 5.6 | 7 | 10.5 | 14 | |
| The working pressure | MPa | 0.7 | 0.7 | 0.7 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
| The water temperature | ℃ | 95 | 95 | 95 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | |
| Return water temperature | ℃ | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | |
| Design the thermal efficiency | % | 93.43 | 93.51 | 92.94 | 93.09 | 93.00 | 93.00 | 94.05 | 94 | 94.06 | 94.15 | 94.02 | 94.1 | 94.12 | |
| Water capacity | L | 1520 | 1760 | 1950 | 2520 | 2930 | 4300 | 5820 | 8000 | 10860 | 13500 | 15500 | 24000 | 26000 | |
| Water outlet | mm | 50 | 65 | 80 | 80 | 100 | 100 | 150 | 150 | 200 | 200 | 200 | 250 | 250 | |
| Feed water inlet | mm | 50 | 65 | 80 | 80 | 100 | 100 | 150 | 150 | 200 | 200 | 200 | 250 | 250 | |
| Drain valve | mm | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50*3 | 50*3 | 50*3 | |
| Chimney | mm | 220 | 220 | 280 | 330 | 330 | 400 | 450 | 500 | 600 | 650 | 750 | 1000 | 1200 | |
| Size | Length | mm | 2450 | 2750 | 3050 | 3200 | 3500 | 3900 | 4350 | 5400 | 5500 | 5900 | 6800 | 8000 | 8400 |
| Width | mm | 1450 | 1450 | 1480 | 1690 | 1690 | 1800 | 2160 | 2240 | 2380 | 2450 | 2700 | 3100 | 3200 | |
| Height | mm | 1800 | 1800 | 1970 | 2270 | 2270 | 2504 | 2578 | 2600 | 2880 | 3050 | 3100 | 3600 | 4200 | |
| Size of base | Length | mm | 2000 | 2200 | 2500 | 2700 | 2950 | 3580 | 3850 | 4960 | 4960 | 5720 | 6400 | 7500 | 8000 |
| Width | mm | 900 | 900 | 900 | 1300 | 1300 | 1400 | 1600 | 1700 | 1800 | 2000 | 2100 | 2300 | 2400 | |
| Fuel consumption | N.G | Nm³/H | 38.24 | 52.4 | 76.89 | 115.16 | 153.69 | 228.44 | 303.96 | 367.8 | 455.88 | 607.3 | 735.3 | 1193.7 | 1452 |
| Light oil | KG/H | 31.56 | 43.28 | 63.56 | 95.18 | 127.07 | 188.45 | 250.79 | 326.6 | 377.46 | 501.5 | 633.2 | 985.1 | 1258 | |
| City gas | Nm³/H | 81.26 | 111.35 | 163.4 | 244.72 | 326.6 | 485.35 | 645.9 | 824 | 968.7 | 1290 | 1630 | 2536 | 3146 | |
| Transport weight | kg | 3000 | 3500 | 4000 | 4600 | 6000 | 7600 | 10000 | 12000 | 15000 | 18600 | 23600 | 34000 | 41000 | |
From Wilford’s published data sheet. Boilers are built to order — the quotation confirms the final figures.
Common questions
Questions about the WNS
- What type of boiler is the WNS?
- Horizontal pressurised fire tube gas hot water boiler, also for diesel.
- Who manufactures the WNS?
- Wilford (Zhangjiagang Wilford Thermal Co., Ltd.), an industrial boiler manufacturer and supplier in Zhangjiagang, China, since 1998. The WNS is designed and built in its own boiler factory, which holds the class B boiler licence, ASME S with National Board registration, and ISO 9001.
- What output and pressure does the WNS cover?
- The WNS covers 0.35–14 MW at 0.7–1 MPa, in 13 standard sizes. Every size is listed in the parameter table on this page.
- Which fuels can the WNS use?
- Natural gas / LPG, diesel / heavy oil. The heat source is matched to the energy available on site; tell us which one you will use.
- What do you need for a quotation?
- Output, working pressure, fuel, power supply (for electric units), the application and the destination country.
Oil & Gas Fired Boilers
Related series
Quotation
Quote for the WNS
Tell us the output, working pressure, fuel and application. An engineer replies with a model selection and a quotation.
- Phone+86-512-5679 1900