Skip to content

Steam · LDR series

LDR Vertical Electric Steam Boiler

Vertical electric steam boiler with fully submerged heating elements — 4 standard sizes.

LDR Vertical Electric Steam Boiler
Output
0.15–0.5 t/h
Working pressure
0.7–1 MPa
Standard sizes
4
Fuel
Electric

Design

Vertical design electric steam boiler, the heating elements are completely submerged in water and completely insulated-high efficiency and minimum radiation losses.

Medium
Steam
Fuel
Electric
Output
0.15–0.5 t/h
Working pressure
0.7–1 MPa
Standard sizes
4 · LDR0.15 – LDR0.5
Rated voltage
3N AC 50Hz 380V

All electrical components with CE and UL marks –ensure safety and long life service.

After precision calculation&design, boiler could quickly and efficiently reach work pressure. Using low heat load surface heating elements– not easily melted or softened. Each component with water pressure and withstand voltage test. Boiler could immediately work after connecting to power and water supply. Nearly 100% thermal efficiency–quiet, clean, more in line with environmental requirements, No atmospheric emissions NOx (nitrogen oxides)

Features

Swipe →
  1. 01 / 07

    All electrical components with CE and UL marks –ensure safety and long life service.

  2. 02 / 07

    Quickly start and stop, big operation load adjusting range, easily handling.

  3. 03 / 07

    Each heating element use a concentrated beam flange connection, independently arrangement, simple structure, high mechanical strength, safe, reliable, convenient replacement, long service life.

  4. 04 / 07

    Flexible working methods, could set either manual or automatic mode.”

  5. 05 / 07

    Unique power switching function, could be regulated based on actual demand of steam power, make same usage time/frequency, improve equipment service life.

  6. 06 / 07

    When electric boiler heating element in a group has problem, could immediate stop operation the destroyed heating group and cut off power supply.”

  7. 07 / 07

    Vertical structure, compact and beautiful, elegant style, classic color, save room space and easily installation.”

Technical parameters

LDR series

Every standard size with output, pressure, fuel consumption, connections, dimensions and weight. Boilers are built to order — the quotation confirms the final figures.

Ask for drawings →

Swipe the table for all sizes

LDR Vertical Electric Heating Steam Boiler
TypeLDR0.15LDR0.2LDR0.3LDR0.5
ProjectUnit
Rated evaporationt/h0.150.20.30.5
Rated working pressureMPa0.7/1.00.7/1.00.7/1.00.8/1.0
Saturated steam temperature℃170/193170/193170/193170/193
Input PowerKW108144216360
Input currentA162216324540
Rated pressureV3N AC 50Hz 380V
Power×GroupKW×P18×618×8/24×627×836×10
a Main steam valve diameterDN25253250
b Safety valve diameterDN25252540
c Inlet diameterDN15152525
d Blowoff Valve diameterDN25254040
Overall sizeLmm1100115013001450
Wmm95095011001350
Hmm1950200021002300
Weightkg350450680980

We can provide customized products for specific power supply in the world.

From Wilford’s published data sheet. Boilers are built to order — the quotation confirms the final figures.

Projects

LDR in operation

All projects →

Common questions

Questions about the LDR

What type of boiler is the LDR?
Vertical electric steam boiler with fully submerged heating elements.
Who manufactures the LDR?
Wilford (Zhangjiagang Wilford Thermal Co., Ltd.), an industrial boiler manufacturer and supplier in Zhangjiagang, China, since 1998. The LDR is designed and built in its own boiler factory, which holds the class B boiler licence, ASME S with National Board registration, and ISO 9001.
What output and pressure does the LDR cover?
The LDR covers 0.15–0.5 t/h at 0.7–1 MPa, in 4 standard sizes. Every size is listed in the parameter table on this page.
What power supply does the LDR need?
Standard units are built for 3N AC 50 Hz 380 V. Tell us your local supply voltage and frequency with the enquiry.
What do you need for a quotation?
Output, working pressure, fuel, power supply (for electric units), the application and the destination country.

Electric Boilers

Related series

All electric boilers →

Quotation

Quote for the LDR

Tell us the output, working pressure, fuel and application. An engineer replies with a model selection and a quotation.

Optional · PDF, image, CAD, Office or ZIP · up to 3 files, 8 MB each

We use your details only to answer your enquiry. The form is protected by Cloudflare Turnstile.