Hot water · CWDR series
CWDR Horizontal Electric Hot Water Boiler
Horizontal electric hot water boiler at atmospheric pressure — 17 standard sizes.

- Output
- 0.7–7 MW
- Working pressure
- Atmospheric
- Standard sizes
- 17
- Fuel
- Electric
Design
No noise, no pollution, clean and sanitary, it is a truly green and environmentally friendly product;
- Medium
- Hot water
- Fuel
- Electric
- Output
- 0.7–7 MW
- Working pressure
- Atmospheric
- Standard sizes
- 17 · CWDR 0.7 – CWDR 7
Use high-quality stainless steel heating tubes or imported alloy steel electric heating tubes to ensure safe and long-term operation of the boiler.
9: According to user requirements, thermal energy storage equipment can be designed using nighttime peak and valley electricity.
Address:9na Calle Poniente y 4ta Ave. Norte # 2-14C, Santa Tecla, La Libertad EI Salvador
Gallery
CWDR Horizontal Electric Hot Water Boiler
2 images
Technical parameters
CWDR series
Every standard size with output, pressure, fuel consumption, connections, dimensions and weight. Boilers are built to order — the quotation confirms the final figures.
Ask for drawings →Swipe the table for all sizes
| Size | CWDR 0.7-85/60 | CWDR 0.8-85/60 | CWDR 0.9-85/60 | CWDR 1.0-85/60 | CWDR 1.05-85/60 | CWDR 1.2-85/60 | CWDR 1.4-85/60 | CWDR 1.5-85/60 | CWDR 1.6-85/60 | CWDR 1.8-85/60 | CWDR 2-85/60 | CWDR 2.1-85/60 | CWDR 2.5-85/60 | CWDR 2.8-85/60 | CWDR 4.2-85/60 | CWDR 5.6-85/60 | CWDR 7-85/60 | ||
| Project | Unit | ||||||||||||||||||
| Rated heating capacity | MW | 0.7 | 0.8 | 0.9 | 1 | 1.05 | 1.2 | 1.4 | 1.5 | 1.6 | 1.8 | 2 | 2.1 | 2.5 | 2.8 | 4.2 | 5.6 | 7 | |
| Total heating capacity | 10 4 kcal | 58.3 | 66.7 | 75.0 | 83.3 | 87.5 | 100.0 | 116.7 | 125.0 | 133.3 | 150.0 | 166.7 | 175.0 | 208.3 | 233.3 | 350.0 | 466.7 | 583.3 | |
| Rated working pressure | MPa | Ordinary pressure | |||||||||||||||||
| Input Power | KW | 700 | 800 | 900 | 1000 | 1050 | 1200 | 1400 | 1500 | 1600 | 1800 | 2000 | 2100 | 2500 | 2800 | 4200 | 5600 | 7000 | |
| Input current | A | 1050 | 1200 | 1350 | 1500 | 1575 | 1800 | 2100 | 2250 | 2400 | 2700 | 3000 | 3150 | 3750 | 4200 | 6300 | 8400 | 10500 | |
| Rated Voltage | V | 3PN380 50Hz | |||||||||||||||||
| a Water outlet diameter | DN | 100 | 100 | 100 | 100 | 100 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 200 | 200 | 200 | 200 | 250 | |
| b Water inlet diameter | DN | 100 | 100 | 100 | 100 | 100 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 200 | 200 | 200 | 200 | 250 | |
| c Water return diameter | DN | 100 | 100 | 100 | 100 | 100 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 200 | 200 | 200 | 200 | 250 | |
| d Blowoff Valve diameter | DN | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |
| e Expansion tube diameter | DN | 100 | 100 | 100 | 100 | 100 | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 200 | 200 | 200 | 200 | 250 | |
| Overall size | Length | L mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2400 | 2400 | 2400 | 2800 | 2800 | 2800 | 2800 | 2800 | 4300 | 5400 | 6500 |
| Width | W mm | 1250 | 1250 | 1250 | 1250 | 1250 | 1250 | 1350 | 1350 | 1350 | 1650 | 1650 | 1650 | 1650 | 1650 | 2260 | 2260 | 2260 | |
| Height | H mm | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 2100 | 2100 | 2100 | 2300 | 2300 | 2300 | 2300 | 2300 | 2300 | 2300 | 2300 | |
| Specifications of single electric control box | A | 1200 | 1200 | 1200 | 1500 | 2000 | 2000 | 2200 | 2200 | 1200 (2) | 1500 (2) | 2000 (2) | 2200 (2) | 2200 (2) | 2000 (3) | 2000 (4) | 2000 (5) | 2000 (7) | |
| B | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||
| C | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | ||
| Weight | T | 1.3/1.8 | 1.5/2.0 | 1.6/2.3 | 1.8/2.4 | 1.9/2.4 | 2.0/2.5 | 2.2/2.9 | 2.3/3.0 | 2.4/3.2 | 2.6/3.6 | 2.8/3.8 | 3.0/4.1 | 3.3/4.4 | 3.5/5.2 | 4.8/6.2 | 5.8/7.7 | 7.4/9.8 | |
From Wilford’s published data sheet. Boilers are built to order — the quotation confirms the final figures.
Projects
CWDR in operation
Common questions
Questions about the CWDR
- What type of boiler is the CWDR?
- Horizontal electric hot water boiler at atmospheric pressure.
- Who manufactures the CWDR?
- Wilford (Zhangjiagang Wilford Thermal Co., Ltd.), an industrial boiler manufacturer and supplier in Zhangjiagang, China, since 1998. The CWDR is designed and built in its own boiler factory, which holds the class B boiler licence, ASME S with National Board registration, and ISO 9001.
- What output and pressure does the CWDR cover?
- The CWDR covers 0.7–7 MW at atmospheric pressure, in 17 standard sizes. Every size is listed in the parameter table on this page.
- What power supply does the CWDR need?
- Standard units are built for 3N AC 50 Hz 380 V. Tell us your local supply voltage and frequency with the enquiry.
- What do you need for a quotation?
- Output, working pressure, fuel, power supply (for electric units), the application and the destination country.
Electric Boilers
Related series
Quotation
Quote for the CWDR
Tell us the output, working pressure, fuel and application. An engineer replies with a model selection and a quotation.
- Phone+86-512-5679 1900
- WhatsApp+86 177 9859 7687
- Emailmanager@wilfordboiler.com