+86 136 0156 8070
  136 0156 8070
You are here: Home » Products » Steam Boiler » Electric Steam Boiler » WDR horizontal electric steam boiler » WDR Horizontal Electric Heating Steam Boiler
WDR Horizontal Electric Heating Steam Boiler WDR Horizontal Electric Heating Steam Boiler
WDR Horizontal Electric Heating Steam Boiler WDR Horizontal Electric Heating Steam Boiler

WDR Horizontal Electric Heating Steam Boiler

Share to:

Above products are powerful horizontal steam boilers.Electrical heating tube with high quality with normal service life around 20,000 hours.Thermal efficiency is nearly 99%, environment friendly.

  • WDR
  • WILFORD
  • 1t/h
  • 10t/h

Product
Electric as heat energy, no heat loss and smoke heat loss, thermal efficiency can reach above 98%. 

Using high quality stainless steel electric heating tube, to ensure the safety and effectiveness, durable operation, electric heating element in each group USES the cluster type flange connection, independent setting, high mechanical strength, safe and reliable, with electric heating element block cutting, easy to change, the service life is long; 
All electrical components have CE and CCC certification to ensure product safety and service life; 
The horizontal structure has great steam space, good quality;


 The steam boiler design structure

 •          All electrical components with CE and CCC certification to ensure product safety and life.
 •          Each group of heating component is equipped with clustered flange connection, with independent design, simple structure, high mechanical strength, which is safe, reliable and easy for replacement.
 •          It has a large steam room steam and good quality;
 •          Electromechanical installation is separate, and electrical control components are away from heat which is favorable for thermal dissipation protection.
 •         PLC microcomputer programmable control and display device can display the status of operating parameters and fault alarm, which realizes automatic control via the HMI.

data
The steam boiler Technical data:

       Type                WDR0.75        WDR1        WDR1.5        WDR2        WDR3        WDR4
       Project        Unit                                                      
       Rated evaporation        t/h        0.75        1        1.5        2        3        4
       Rated working pressure        MPa        1.0/1.25        1.0/1.25        1.0/1.25        1.0/1.25        1.0/1.25        1.0/1.25
Staturated steam temperature                184/193        184/193        184/193        184/193        184/193        184/193
       Input Power        KW        540        720        1080        1440        2160        2880
       Input current        A        810        1080        1620        2160        3240        4320
       Rated pressure        V        3N AC 50Hz 380V
       Power×Group        KW×P        36×15        36×20        36×30        36×40        36×60        36×80
       Main valve caliber        DN        40        40        65        65        80        100
       Safty valve caliber        DN        2×40        2×40        2×40        2×40        2×40        2×50
       Infall caliber        DN        25        25        25        25        40        40
       Sewage valve caliber        DN        40        40        40        40        40        40
       Overall size        L  mm        2800        2950        3450        3500        3950        4100
                L1  mm        2400        2500        3050        2880        3200        3550
                W  mm        1800        1900        2180        2000        2100        2480
                W1  mm        1550        1600        1430        1880        1980        2120
                H  mm        1550        1600        2100        2500        2650        2980
                H1  mm        1300        1350        1850        1900        2100        2200
       
   Control cabinet overall size
     
        
       A   mm        1200        1200        1500        1800        2100        2400
       B  mm        500        600        600        600        600        600
       C  mm        1800        1800        2000        2000        2200        2200
       Weight        T        1.6/2.0        1.8/2.2        2.2/2.7        2.8/3.3        3.5/4.1        4.5/5.2



Detail-p
wilford1

wilfordwdr3
wilford4
wilford6
wilford9
wilford3

drawing
wdr_system installation drawings

jiangsu industry steam boiler structure


customer
customer visit

MANUFACTURE
electric steam boiler industry boiler

OURCERTIFICATE
horizontal electric steam boiler certificates

Our Company
high quality steam boiler factory


CONTACT US

Address: No5, Nanyuan Road Economic Development Zone, Zhangjiagang
Tel: +86-512-5817 0166
Fax: +86-512-5869 8850
Email: manager@wilfordboiler.com
WhatsApp:+86 136 0156 8070
WeChat: 136 0156 8070

FOLLOW US

SEND YOUR EMAIL

Questions or concerns?We’re here to help.

Site map    © Copyright 2002-2017   Zhangjiagang Wilford Thermal Co.,Ltd.